ELGi Airmate Refrigerant Air Dryer

Compressed air drying is an essential and is an important part of air treatment process. Compressed air contains water, dirt, wear particles, bacteria and even degraded lubricating oil. All these impurities mix together to form an abrasive sludge. This sludge is often acidic and accelerates wear and tear of tools, pneumatic machinery, block valves and orifices. This results in costly air leaks and high maintenance. It also corrodes pipes and can bring production process to a standstill. Only compressed air that is totally clean and dry will ensure reliable working of compressed air systems and maximum savings. The favored method of drying the compressed air is through refrigeration dryers.

Elgi offers a reliable solution through Elgi Airmate Refrigerant Air Dryers. The dryers ensure longer life of compressed air systems through efficient removal of the condensate and contaminants

FEATURESTECHNICAL SPECIFICATIONSBROCHUREREQUEST A QUOTE
  • High Efficiency Thermal Mass Technology
  • Microprocessor Based Digital Dew Point Controller
  • 100% Modulating Cycle Controller
  • Electronic Auto Condensate Drain
  • Ozone Friendly Refrigerant
  • Compact
  • Low Pressure Drop
ELGI Model Flow Capacity
Scfm
Max. Working
Pressure
M3/min psi
Nominal Power
Consumption
(Air & Water)
HP
Compressed Air
Connections
Cooling
Media
Dimensions
Length (in)
Width (in)
Height (in)
Gross Weight
(Air & Water)
Nominal Power Supply: 1Ph/115V/60Hz
EGRD010 10 0.28 232 0.25|-- 3/8" NPT Air 12.2 13.6 17.1 46--
EGRD015 15 0.42 232 0.27|-- 3/8" NPT Air 12.2 13.6 17.1 55--
EGRD020 20 0.57 232 0.28-- 1/2" NPT Air 14.6 20.2 18.7 60--
EGRD030 35 0.99 232 0.38-- 1/2" NPT Air 14.6 20.2 18.7 67--
EGRD040 50 1.42 232 0.40-- 1/2" NPT Air 14.6 20.2 18.7 76--
EGRD050 65 1.84 232 0.44-- 1/2" NPT Air 14.6 20.2 18.7 84--
EGRD080 75 2.12 203 0.60-- 1” NPT Air 13.5 16.5 29.1 84--
EGRD100 100 2.83 203 0.93-- 1" NPT Air 13.5 17.5 29.1 95--
EGRD150 125 3.54 203 1.34-- 1" NPT Air 13.5 17.5 29.1 97--
EGRD175 150 4.25 203 1.40-- 1" NPT Air 19.0 17.9 32.4 123--
EGRD200 175 4.95 203 1.47-- 1" NPT Air 21.8 22.8 34.8 146--
Nominal Power Supply: 1Ph/230V/60Hz
EGRD150 125 3.54 203 1.40-- 1" NPT Air 13.5 17.5 29.1 97--
EGRD175 150 4.25 203 1.54-- 1" NPT Air 19.0 17.9 32.4 123
EGRD200 175 4.95 203 1.60-- 1" NPT Air 21.8 22.8 34.8 146--
EGRD250 220 6.23 203 1.67-- 1" NPT Air 21.8 22.8 34.8 150--
EGRD300 300 8.49 203 2.01-- 2” NPT Air 21.8 24.6 38.3 234--
EGRD400 375 10.61 203 2.95-- 2” NPT Air 21.8 24.6 38.3 239--
EGRD500 480 13.58 203 3.08-- 2" NPT Air 26.1 28.5 43.5 362
Nominal Power Supply: 3Ph/460V/60Hz
EGRD600 600 17.00 203 3.55 | 3.04 ANSI 3”#150 Air | Water | Air 35.0 39.3 62.5 529 | 496
EGRD750 800 22.60 203 4.35 | 3.91 ANSI 3”#150 Water 35.0 39.3 62.5 534 | 500
EGRD900 900 25.40 203 5.22 | 4.55 ANSI 3”#150 Air | Water 35.0 39.3 62.5 606 | 564
EGRD1100 1000 28.30 203 6.16 | 5.02 ANSI 3”#150 Air | Water 35.0 39.3 62.5 608 | 567
EGRD1254 1250 35.30 203 7.50 | 6.57 ANSI 3”#150 Air | Water 35.0 39.3 62.5 686 | 635
EGRD1552 1500 42.40 203 8.58 | 6.70 ANSI 3”#150 Air | Water 44.6 49.0 68.8 1021 | 950
EGRD1750 1750 49.50 203 10.05 | 7.91 ANSI 3”#150 Air | Water 44.6 49.0 68.8 1186 | 1098
EGRD2000 2000 56.60 203 11.50 | 9.65 ANSI 3”#150 Air | Water 44.6 49.0 68.8 1190 | 1102
EGRD2900 2500 70.70 203 13.10 | 11.26 ANSI 3”#150 Air | Water 44.6 49.0 68.8 1349 | 1239
Note:
  • Reference Condition for Inlet flow capacity: 1. Ambient Temperature – 100°F / 2. Inlet compressed air temperature 100°F / 3. Inlet Pressure – 100 psig.
  • All data mentioned above is measured according to ISO 7183, with standard voltages, at 38-41° F dew point.
  • High pressure dryers and high ambient temperature dryers are available on request.
  • Standard scope of supply includes only electronic drain valves up to EGRD500 & zero loss drains from EGRD600.
Finance Options